Electronic room thermostat with batteries, 3 temperature levels
-
DESCRIPTION
General features0
Electronic room thermostat with microprocessor to control heating and air conditioning installations.
CH115-16 model has the possibility to connect an auxiliary sensor for the minimum temperature T/min and the maximum temperature T/max.
- Wide display with graphic icons combined with frontal keys for choosing the operation mode.
- Possibility to visualize Celsius or Fahrenheit temperature values.
- Battery operation life over 4 years.
- Low battery charge indication.
- Maximum ambient temperature 45 °C.
- Dimensions 135 x 83 x 21mm.
Electric features- Power supply with two 1,5V AAA alkaline long life batteries.
- Micro disconnection 1B.
- Voltage-free switching contact.
-
ADVANTAGES
0
Electronic room thermostat with microprocessor to control heating and air conditioning installations.
CH115-16 model has the possibility to connect an auxiliary sensor for the minimum temperature T/min and the maximum temperature T/max.
Advantages -
TECHNICAL SPECIFICATION
CODE COLOR TEMPERATURE RANGE DIFFERENTIAL * POWER SUPPLY CONTACT RATING CH115 White 2 ÷ 40 °C 0.5 K 2 batteries AAA 1.5V 5(3)A 250V~ CH116 Silver 2 ÷ 40 °C 0.5 K 2 batteries AAA 1.5V 5(3)A 250V~ CH117 Anthracite 2 ÷ 40 °C 0.5 K 2 batteries AAA 1.5V 5(3)A 250V~ CH115-16 White 2 ÷ 40 °C 0.5 K 2 batteries AAA 1.5V 16(4)A 250V~ * Differential values are referred to a thermal gradient of 4K/h -
HOMOLOGATION AND INSTALLATION
Homologation
- Complies with EN 60730-2-9 standards.
- ErP Class IV; 2% (Reg. EU 811/2013 – 813/2013).
Installation and use- Wall mounting or in 3-module embedded box (503) or in round box with axle spacing of 60 mm.
- It is supplied with a base suitable for installation in embedded (503) rectangular or round boxes, or on the wall.
- Two-wire connection with the user.
- No changes are necessary to the existing system.
- 3 operation modes:
– COMFORT
– ECONOMY
– OFF can be used as “antifreeze” mode or to shutdown completely the system (OFF). - 3 set temperatures:
– COMFORT operates system’s comfort temperature that can be set from 2°C to 40°C.
– ECONOMY operates system’s economy temperature that can be set from 2°C to 40°C.
– OFF temperature set in the “regulation” mode from 0 to 7°C to ensure frost protection function. - SUMMER-WINTER control by pressing simultaneously the keys
-
TECHNICAL LITERATURE
- CH115 EN technical data sheet
- CH115 EN instructions
- CH115-16 EN instructions
- CH115 ES hoja de instrucciones
- CH115-16 ES hoja de instrucciones
- CH115 FR feuille d'instructions
- CH115-16 FR feuille d'instructions
- CH115 RU technical data sheet
- CH115 RU instructions
- CH115-16 RU instructions
- BIM Object CH115
- BIM Object CH116
- BIM Object CH117
- BIM Object CH115-16
-
FAQS