Thermostats with capillary and bulb for remote mounting, IP65
-
DESCRIPTION
General features0
Thermostats with capillary to control the temperature in the boilers, in the air-conditioning and cooling systems, in household appliances, in electrical furnaces.
Waterproof execution IP65
- Sealable casing after the calibration is done.
- Sensing element with stainless steel diaphragm.
- Copper bulb and capillary.
- Copper bulb and capillary, tinned for types C04C2.. and C04D2..
- Base in shock-proof self-extinguishing thermoplastic material V0.
- Electrical connection output with G 1/2 cable gland.
- The storage and transport temperature corresponds to the thermostat’s body admissible temperature.
- Unit weight: 0,16 Kg.
Electric features- Two directions microswitch of instant action with AGcdO contacts.
- Contact parameters in compliance with EN 60730-1: 15(6)A 250V~ 50Hz.
-
ADVANTAGES
0
Thermostats with capillary to control the temperature in the boilers, in the air-conditioning and cooling systems, in household appliances, in electrical furnaces.
Waterproof execution IP65
Advantages -
TECHNICAL SPECIFICATION
CODE REGULATION TYPE TEMPERATURE RANGE DIFFERENTIAL CALIBRATION ACCURACY MAXIMUM BULB TEMPERATURE PROTECTION DEGREE C04A3Y external 10 ÷ 90 °C 6 ± 1 K ± 3 °C 150 °C IP65 C04B3Y external 50 ÷ 300 °C 8 ± 2 K ± 3 °C 350 °C IP65 C04C2Y external - 20 ÷ 40 °C 2 ± 0.5 K ± 2 °C 80 °C IP65 C04D2Y external - 35 ÷ 20 °C 2 ± 0.5 K ± 2 °C 80 °C IP65 C04E3Y external 40 ÷ 120 °C 6 ± 2 K ± 3 °C 150 °C IP65 C04C2RIY * internal - 20 ÷ 40 °C 2 ± 0.5 K ± 2 °C 80 °C IP65 * delivery time and minimum purchase quantity upon request The differential is subtracted from the range value. The differential values refer to a thermal gradient of 1K/hour in liquid and 4K/hour in air -
HOMOLOGATION AND INSTALLATION
Homologation
- Compliance with standards EN 60947-5-1, EN 60730-1
- Compliance with Directive 2014/68 / EC (PED);
- ENEC certificates.
Installation and use- Wall mounting for the thermostat body.
- The bulb with capillary can be mounted remotely and is provided with seal caps or copper sheath with GC 1/2 connection.
- When the temperature increases: 1-2 are opening, 1-4 are closing.
- Liquid expansion function.
- TECHNICAL LITERATURE
-
FAQS