Capillary limit thermostat with manual reset
-
DESCRIPTION
General features0
Capillary limit thermostat with manual reset
- Gold-plated contact version code 9K2-Q0836-00A.
- Failure safe function.
- Tolerance +0 -6 ° C
- Differential: manual reset
- Thermal gradient 1 ° C / min
- Control head temperature limit T 85
- Max tolerance temperature of the sensitive element T 120
- Type of action 1B
- Insulation class I
- Overvoltage category II
- Rated impulse voltage 4 kV
- Use heat-resistant cables min. T 140
- Earthing device with screw terminals
- Pollution degree 2
- Other temperature ranges and versions available on request.
- Compliance with CE standard 0497 (PED)
Electric features- SPDT contacts: C/NO/NC.
- Contact rating 16(4)A 250Vca, 6(1)A 400Vca, with gold plated contacts 100mV 0,3 A.
-
ADVANTAGES
0
Capillary limit thermostat with manual reset
Advantages -
TECHNICAL SPECIFICATION
CODE ADJUSTMENT RANGE PROTECTION DEGREE TYPE OF REGULATION BULB DIMENSIONS mm CAPILLARY LENGTH mm PACK QTY 9K6-70316-00A * 70 °C IP55 fixed Ø 5 x 95 Inox 500 10 9K6-99326-00A * 100 °C IP55 fixed Ø 6.5 x 73 1000 10 9K2-11326-00A 90 ÷ 110 °C IP55 internal Ø 6.5 x 73 1000 10 9K2-Q0836-00A * SPECIAL MODEL - CHIMNEY LIMITER THERMOSTAT 70 ÷ 110 °C IP55 internal Ø 5 x 90 1500 10 * delivery time and minimum purchase quantity upon request -
HOMOLOGATION AND INSTALLATION
HomologationInstallation and use
- TECHNICAL LITERATURE
-