Remote relay actuator for IntelliComfort CH150R
-
DESCRIPTION
General features0
CH171D actuator, coupled with Intellicomfort CH150R programmable thermostat by means of a bipolar cable, allows the remotely control of two users that typically represent the heating system and the humidification system.
- Operating temperature: 45 °C.
- Storage and transport ambient temperature: -25 ÷ 60 °C.
- Voltage-free switching contacts.
- Software class A.
- Double insulation.
Electric features- Power supply: 230V 50 Hz.
- Absorbed power: 2VA.
- Output relay parameters: 5(3)A 250 Vca.
- Voltage-free switching contacts.
- Disconnection type 1B.
-
ADVANTAGES
0
CH171D actuator, coupled with Intellicomfort CH150R programmable thermostat by means of a bipolar cable, allows the remotely control of two users that typically represent the heating system and the humidification system.
Advantages -
TECHNICAL SPECIFICATION
CODE MOUNTING POWER SUPPLY CONTACT RATING PROTECTION DEGREE CH171D DIN rail 230Vca 50Hz 5(3)A 250Vca IP40 (back panel) -
HOMOLOGATION AND INSTALLATION
Homologation
- Complies with EN60730-1 standards.
- In conformity with R&TTE EN300 220-3, EN 301 489-03 directives.
Installation and use- Installation shall be performed according to the current rules.
- The distance between the actuator and transmitter must not exceed 100 m.
- Connect the cables to the terminal board base according to the shown wiring diagrams.
- Back panel mounting.
- CH171D actuator, coupled with a Fantini Cosmi programmable thermostat by means of a bipolar cable, allows the remotely control of two users that typically represent the heating system and the humidification system.
- The bipolar cable that connects the programmable thermostat to CH171D actuator has two functions:
– Programmable thermostat power supply;
– Communication bus of the ON/OFF commands sent from the programmable thermostat to CH171D. - The receiving device operation CHARACTERISTICS three led giving the following indications:
– POWER ON: when this led is on it indicates that the actuator is properly powered. Instantaneous and quickly flashing shows the receipt of the data sent via radio from the programmable thermostat.
– RELAY CONTACT FOR HEATING: when this led is on it indicates that the relay contact used for heating is closed, otherwise it will be open.
– RELAY CONTACT FOR HUMIDIFICATION: it indicates, if is on that the relay contact used for humidification is closed, otherwise it will be open.
- TECHNICAL LITERATURE
-
FAQS